Regulatory Reform (Fire Safety) Order 2005 · England & Wales
RRFSO Compliant
Assessment
48-HR REPORT

Every exit clear.
Every risk scored and resolved.

Thermal cameras, floor plans, and 12 years of fire code memorised. We walk your building so your Responsible Person can sign with confidence — not a maybe.

RRFSO 2005 CompliantFire Safety Act 2021Building Safety Act 2022FPA Member
LIVE
0
Assessments Completed
Since 2014
LIVE
0hrs
Avg. Report Turnaround
Guaranteed ≤48 hrs
LIVE
0.0%
Client Pass Rate
First assessment
LIVE
0+
Years RRFSO Experience
England & Wales
Live Audit Methodology

What your assessment covers

Toggle each module to see how a completed FireAudit report reads. Every unchecked item below is a potential liability in your building right now.

Modules Assessed
0/4
MOE

Means of Escape

Escape routes, final exits, travel distances, and door hardware compliance.

Unchecked
RRFSO Art. 14 · FSA 2021 §1
Sample Findings — 4 items requiring action
critical
MOE-01

Final exit door to car park fitted with key-operated deadlock — no thumb-turn or panic bar.

Action: Replace lock with EN 1125-compliant panic hardware.
24 hours
high
MOE-02

Storage boxes reducing corridor width to 820mm at north stairwell landing.

Action: Remove obstruction; enforce clear-width policy (min. 1000mm).
48 hours
high
MOE-03

Fire door self-closer on 2nd floor east wing removed — door propped open with wedge.

Action: Reinstate BS EN 1154-compliant self-closer; remove wedge.
48 hours
medium
MOE-04

Travel distance from open-plan office exceeds 45m to nearest final exit.

Action: Review layout; consider additional escape route or layout reconfiguration.
30 days
11 of 15 checks passed — compliant
FD

Fire Detection & Warning

Detector types, coverage, alarm categories, and maintenance records.

Unchecked
RRFSO Art. 13 · BS 5839-1:2017
Sample Findings — 3 items requiring action
high
FD-01

Smoke detector absent from server room — heat detector present but category inadequate.

Action: Install multi-sensor detector; update cause-and-effect matrix.
7 days
medium
FD-02

Manual call point on ground floor obscured by display stand — not visible from 3m.

Action: Relocate display; ensure unobstructed 3m sightline to all MCPs.
48 hours
medium
FD-03

Last service record for fire alarm panel dated 14 months ago — BS 5839 requires 6-monthly.

Action: Commission service visit; maintain log in fire safety file.
14 days
8 of 11 checks passed — compliant
COMP

Compartmentation

Fire-rated walls, ceilings, service penetrations, and structural fire separation.

Unchecked
RRFSO Art. 14 · Approved Doc B
Sample Findings — 2 items requiring action
critical
COMP-01

Cable penetrations through 60-minute rated wall (server room boundary) left unsealed.

Action: Apply intumescent sealant to all penetrations; photograph and record.
48 hours
high
COMP-02

Suspended ceiling tiles removed in roof void — fire barrier integrity compromised.

Action: Reinstate tiles or install fire-rated void barrier; engage specialist contractor.
7 days
7 of 9 checks passed — compliant
SIG

Signage & Emergency Lighting

Escape route signage, pictograms, emergency luminaire testing and coverage.

Unchecked
RRFSO Art. 14 · BS 5266-1:2016
Sample Findings — 3 items requiring action
high
SIG-01

Exit sign above 1st floor stairwell door non-illuminated — bulb failed, not replaced.

Action: Replace luminaire; add to monthly visual check schedule.
24 hours
medium
SIG-02

Emergency lighting duration test overdue by 4 months — annual 3-hour test not recorded.

Action: Arrange annual test; record in fire safety logbook.
30 days
low
SIG-03

No directional signage in basement car park — dead-end bay not signed.

Action: Install BS EN ISO 7010:E007 photoluminescent signs at junction points.
30 days
9 of 12 checks passed — compliant
4 modules still unchecked — each represents real liability.
A FireAudit assessment covers 47 checklist items across these four domains.
Get Your Assessment
Sample Report Extract

Risk-scored findings register

Every finding is scored on likelihood × consequence, assigned to an owner, and given a remedial timeline. This is what your 48-hour report looks like.

2CRITICAL
5HIGH
4MEDIUM
1LOW
RefLocationFindingDomainRiskScoreRemedial ActionTimelineOwner
MOE-01Ground Floor — East ExitFinal exit door fitted with key-operated deadlock, no panic hardwareMeans of EscapeCRITICAL
20
Replace with EN 1125 panic bar24 hrsFacilities Manager
COMP-01Server Room Boundary WallCable penetrations through 60-minute rated wall left unsealedCompartmentationCRITICAL
20
Intumescent sealant to all penetrations48 hrsSpecialist Contractor
MOE-02North Stairwell — 1st LandingCorridor width reduced to 820mm by stored boxesMeans of EscapeHIGH
15
Remove obstruction; enforce clear-width policy48 hrsFacilities Manager
MOE-032nd Floor East WingFire door self-closer removed, door propped openMeans of EscapeHIGH
15
Reinstate BS EN 1154 self-closer48 hrsMaintenance
FD-01Server RoomSmoke detector absent — heat detector category inadequateFire DetectionHIGH
12
Install multi-sensor detector7 daysFire Alarm Contractor
COMP-02Roof Void — Zone BSuspended ceiling tiles removed, void barrier compromisedCompartmentationHIGH
12
Reinstate tiles or install fire-rated barrier7 daysSpecialist Contractor
SIG-011st Floor Stairwell DoorExit sign non-illuminated — bulb failedSignage & LightingHIGH
12
Replace luminaire; add to monthly check24 hrsMaintenance
FD-02Ground Floor ReceptionManual call point obscured by display standFire DetectionMEDIUM
8
Relocate display; ensure 3m sightline48 hrsFacilities Manager
MOE-04Open-Plan Office — Floor 2Travel distance exceeds 45m to nearest final exitMeans of EscapeMEDIUM
8
Review layout; consider additional escape route30 daysBuilding Owner
FD-03Fire Alarm PanelService record 14 months old — BS 5839 requires 6-monthlyFire DetectionMEDIUM
6
Commission service visit; update logbook14 daysFire Alarm Contractor
SIG-02Building-WideAnnual 3-hour emergency lighting test overdue by 4 monthsSignage & LightingMEDIUM
6
Arrange annual test; record in fire safety logbook30 daysElectrical Contractor
SIG-03Basement Car ParkNo directional signage — dead-end bay not signedSignage & LightingLOW
3
Install BS EN ISO 7010 photoluminescent signs30 daysFacilities Manager

Risk Score = Likelihood (1–5) × Consequence (1–4). Scores ≥16: Critical · 12–15: High · 6–11: Medium · 1–5: Low. Findings extracted from a representative commercial premises assessment.

Request Full Sample Report
Sector Experience

Built for your compliance context

Different premises, different licensing regimes, different inspection bodies. Our assessments are written to satisfy the specific authority examining yours.

Multi-Site Portfolios

Facilities Managers

Juggling 4–40 sites across commercial, retail, and industrial premises.

RRFSO Art. 9 requires a suitable and sufficient assessment for every non-domestic premises under your control.
Common Gaps We Find
Inconsistent assessment standards across sites
Difficulty tracking remedial action completion
Scheduled review dates falling through the cracks
Evidence gaps when audited by Fire & Rescue Service
What You Receive
Standardised report format across all sites
Portfolio risk dashboard with RAG status
Scheduled review calendar — never miss a date
Action tracker with owner assignment
Discuss Portfolio Pricing
HMO Licensing Deadlines
MOST COMMON

Landlords & HMO Owners

Three-storey HMOs with 5+ residents require a licensed, documented fire risk assessment.

Local authority licensing conditions and the RRFSO place specific duties on the person having control of an HMO.
Common Gaps We Find
Licensing renewal blocked pending FRA documentation
Uncertainty about detection requirements per floor
Tenant turnover increasing ignition risk
Insurance liability without current assessment
What You Receive
LACORS-aligned HMO assessment format
Room-by-room risk findings with photographs
Licensing-ready report accepted by all UK councils
Detection specification to BS 5839-6 Category D
Book HMO Assessment
Ofsted Safeguarding

School Business Managers

Fire safety is a core Ofsted safeguarding check — a gap here is a gap in your inspection.

The RRFSO applies to all educational premises. All staff must receive fire safety training at induction and periodically thereafter.
Common Gaps We Find
Ofsted inspection date confirmed — FRA not current
Staff fire safety training records incomplete
Temporary classroom additions not included in existing FRA
Lack of evidence that review was completed post-refurb
What You Receive
Education-sector FRA accepted by Ofsted inspectors
Staff training register template included
Evacuation drill record and guidance
Covers main building, portacabins, and sports halls
Request Education Assessment
Also covering:Care HomesHotels & Guest HousesPlaces of WorshipCommunity HallsRetail PremisesIndustrial UnitsHealthcare Clinics
Get Started

Value before the ask

Choose your path. Both are free. One just requires a conversation.

Free Pre-Audit Checklist

Instant download · No card required

47-point pre-assessment checklist
Covers all four RRFSO audit domains
Identifies common compliance gaps before assessment day
Accepted format by Fire & Rescue Services
Why FireAudit
RRFSO Compliant
48-Hr Guarantee
2,847 Assessments
97.4% Pass Rate

No spam. Unsubscribe at any time. We process data under UK GDPR.

RRFSO 2005
Fully compliant assessments
Fire Safety Act 2021
External walls & flat doors covered
Building Safety Act 2022
Higher-risk building duties
48-Hour Guarantee
Written report or full refund